Review



custom computer controlled micromanipulation instrument system  (Aurora Scientific)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 86

    Structured Review

    Aurora Scientific custom computer controlled micromanipulation instrument system
    Custom Computer Controlled Micromanipulation Instrument System, supplied by Aurora Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer-controlled+micromanipulation+instrument+system/computer+controlled+custom+instrument+micromanipulation+system/us12398348-534-19-53
    Average 86 stars, based on 1 article reviews
    custom computer controlled micromanipulation instrument system - by Bioz Stars, 2026-10
    86/100 stars

    Images

    Related Articles

    Capsules:

    Article Title: Benefit agent delivery particle
    Article Snippet: The resulting volume-weighted PSD data are plotted and recorded, and the values of the mean, 5th percentile, and 90th percentile are determined. b) The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Consumer product compositions with at least two encapsulate populations
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual capsules are measured via a custom computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery capsules, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada) or equivalent, as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery capsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary capsules on the dry slide.

    Article Title: Benefit agent containing delivery particle
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Articles providing long lasting fragrances
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual microcapsules are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the microcapsules, and which possesses a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada, or equivalent), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the microcapsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Micromanipulation:

    Article Title: Benefit agent delivery particle
    Article Snippet: The resulting volume-weighted PSD data are plotted and recorded, and the values of the mean, 5th percentile, and 90th percentile are determined. b) The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Consumer product compositions with at least two encapsulate populations
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual capsules are measured via a custom computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery capsules, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada) or equivalent, as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery capsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary capsules on the dry slide.

    Article Title: Benefit agent containing delivery particle
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Articles providing long lasting fragrances
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual microcapsules are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the microcapsules, and which possesses a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada, or equivalent), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the microcapsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Suspension:

    Article Title: Benefit agent delivery particle
    Article Snippet: The resulting volume-weighted PSD data are plotted and recorded, and the values of the mean, 5th percentile, and 90th percentile are determined. b) The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Consumer product compositions with at least two encapsulate populations
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual capsules are measured via a custom computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery capsules, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada) or equivalent, as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery capsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary capsules on the dry slide.

    Article Title: Benefit agent containing delivery particle
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Articles providing long lasting fragrances
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual microcapsules are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the microcapsules, and which possesses a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada, or equivalent), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the microcapsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Microscopy:

    Article Title: Benefit agent delivery particle
    Article Snippet: The resulting volume-weighted PSD data are plotted and recorded, and the values of the mean, 5th percentile, and 90th percentile are determined. b) The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Consumer product compositions with at least two encapsulate populations
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual capsules are measured via a custom computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery capsules, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada) or equivalent, as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery capsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary capsules on the dry slide.

    Article Title: Benefit agent containing delivery particle
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual particles are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the delivery particles, and which possess a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the delivery particle suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.

    Article Title: Articles providing long lasting fragrances
    Article Snippet: The diameter and the rupture-force value (also known as the bursting-force value) of individual microcapsules are measured via a computer-controlled micromanipulation instrument system which possesses lenses and cameras able to image the microcapsules, and which possesses a fine, flat-ended probe connected to a force-transducer (such as the Model 403A available from Aurora Scientific Inc, Canada, or equivalent), as described in: Zhang, Z. et al. (1999) “Mechanical strength of single microcapsules determined by a novel micromanipulation technique.” J. Microencapsulation, vol 16, no. 1, pages 117-124, and in: Sun, G. and Zhang, Z. (2001) “Mechanical Properties of Melamine-Formaldehyde microcapsules.” J. Microencapsulation, vol 18, no. 5, pages 593-602, and as available at the University of Birmingham, Edgbaston, Birmingham, UK. c.) A drop of the microcapsule suspension is placed onto a glass microscope slide, and dried under ambient conditions for several minutes to remove the water and achieve a sparse, single layer of solitary particles on the dry slide.



    Similar Products

    86
    Aurora Scientific custom computer controlled micromanipulation instrument system
    Custom Computer Controlled Micromanipulation Instrument System, supplied by Aurora Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer-controlled+micromanipulation+instrument+system/computer+controlled+custom+instrument+micromanipulation+system/us12398348-534-19-53
    Average 86 stars, based on 1 article reviews
    custom computer controlled micromanipulation instrument system - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    90
    Aurora Scientific computer-controlled micromanipulation instrument system
    Computer Controlled Micromanipulation Instrument System, supplied by Aurora Scientific, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer-controlled+micromanipulation+instrument+system/computer+controlled+micromanipulation+instrument+system/us12227720-549-19-53
    Average 90 stars, based on 1 article reviews
    computer-controlled micromanipulation instrument system - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Sutter Instrument Company three axis computer-controlled micromanipulator sutter instruments
    Three Axis Computer Controlled Micromanipulator Sutter Instruments, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer-controlled+micromanipulation+instrument+system/three+axis+computer+controlled+micromanipulator+sutter+instruments/us09313423-116-12-15
    Average 90 stars, based on 1 article reviews
    three axis computer-controlled micromanipulator sutter instruments - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Sutter Instrument Company three-axis computer-controlled micromanipulator sutter instruments
    Three Axis Computer Controlled Micromanipulator Sutter Instruments, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer-controlled+micromanipulation+instrument+system/three+axis+computer+controlled+micromanipulator+sutter+instruments/pm22735456-189-11-15
    Average 90 stars, based on 1 article reviews
    three-axis computer-controlled micromanipulator sutter instruments - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Sutter Instrument Company three-axis computer-controlled micromanipulator sutter instruments v3330
    Three Axis Computer Controlled Micromanipulator Sutter Instruments V3330, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer-controlled+micromanipulation+instrument+system/three+axis+computer+controlled+micromanipulator+sutter+instruments+v3330/pmc03621452-132-11-14
    Average 90 stars, based on 1 article reviews
    three-axis computer-controlled micromanipulator sutter instruments v3330 - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    San Diego Instruments computer-controlled micromanipulator sd instruments
    Computer Controlled Micromanipulator Sd Instruments, supplied by San Diego Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/computer-controlled+micromanipulation+instrument+system/hydraulic+micromanipulator/pm15571342-132-2-3
    Average 90 stars, based on 1 article reviews
    computer-controlled micromanipulator sd instruments - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results